Venous Blood Gas – VBG-ABG correlation

Venous blood gas can be used toestimate systemic CO2 and pH levels.

Possible sites of VBG:

  1. peripheral venous sample (from venipuncture)
  2. central venous sample (from central venous catheter)
  3. mixed venous sample (from distal port of PAC)

Values from VBG:

  1. PvO2 – venous oxygen tension
  2. PvCO2 – venous carbon dioxide tension
  3. pH
  4. SvO2 – oxyhemoglobin saturation
  5. HCO3 – serum bicarbonate

PvCO2, pH, HCO3 – assess ventilation and/or acid-base status

SvO@ – guides resuscitation

PvO2 – no value

 

Correlations:

  1. Central venous sample
    1. pH – 0.03 to 0.05 pH units lower than arterial pH
    2. PvCO2 – 4-5 mm Hg higher than PaCO2
    3. HCO3 – little or no increase
  2. Mixed venous sample – similar tocentral venous sample
  3. peripheral venous sample
    1. pH – 0.02 to 0.04 pH units lower than arterial pH
    2. HCO3 –  1-2 mEq/L higher
    3. PvCO2 – 3-8 mm Hg higher than PaCO2

*varies with hemodynamic stability

 

Reference:

Uptodate.com. (2018). UpToDate. [online] Available at: https://www.uptodate.com/contents/venous-blood-gases-and-other-alternatives-to-arterial-blood-gases?search=venous%20blood%20gas&source=search_result&selectedTitle=1~150&usage_type=default&display_rank=1 [Accessed 22 Oct. 2018].

Advertisements

Tagged: , , ,

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google photo

You are commenting using your Google account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s

%d bloggers like this: